8.4 Export/Import
The results calculated in Integral of Power Dissipated window can be exported (saved) with Save command from main menu or context menu.
The user can save values of space and time integral of power dissipated and energy available in the *.pq3 file.
Example 1: format of *.pq3 file
! QuickWave 3D Integrated Dissipative Power Results Data File ver. 3.6
! Computer time = Wed Aug 22 15:02:52 2018
! Program version v2018:2018.07.24 HN64,OMP
! Task name - .../qw_examp/QW_3D/Standard/Heating/Beefburg/bb_frozen_fdm3d_int_244_6.ta3
! Start iteration number = 8274
! Stop iteration number = 16720
! Current FDTD time [ns] = 1.38141600e+002
! Time step [ns] = 8.38361965e-003
! Enthalpy units - [nJ]
! Enthalpy parameter - enthalpy_electric_magnetic
! Density parameter - All_Region
EnthalpyE
EnthalpyM
EnthalpyT
1.2644838e-005
0.0000000e+000
1.2644838e-005
Energy Available
3.2347098e-003
The format of the *.pq3 contains:
a header with basic simulation information,
a header matrix of calculated space and time integral of power dissipated quantities (EnthalpyE– power dissipated in electric field, EnthalpyM – power dissipated in magnetic field, EnthalpyT - energy stored in electric field),
· a matrix of values of the above quantities,
a header of calculated Energy Available,
a value of the Energy Available.
Previously saved space and time integral of power dissipated and energy available results can be loaded from *.pq3 file and viewed in a text form using Saved Power, Energy & Q Results command from Power, Energy, Q & Temperature label button with commands from Results tab of QW-Simulator Ribbon or using Saved Power, Energy & Q Results command from Results menu of QW-Simulator main menu.