QWED laboratory

Measurement Services

Precision RF/microwave material characterisation using our family of resonators and fixtures. We measure Dk, Df, conductivity σ, resistivity ρ, and surface resistance (Ω/sq) — with clear reports and fast turnaround.

What we measure

Solid dielectrics

  • Parameters: Dk, Df, optional TCK/TCF
  • Frequency coverage: 1–130 GHz (method-dependent)
  • Methods: SPDR 1.1–15 GHz, FPOR 10–130 GHz, TE01δ 1–10 GHz, Q-SCR 10 GHz

Liquids

  • Parameters: Dk, Df
  • Frequency coverage: 15–50 GHz and 110–170 GHz
  • Methods: FPOR liquids 15–50 GHz, DR/Cavity liquids 110–170 GHz

Conductors

  • Parameters: σ (conductivity)
  • Frequencies: 13.9, 20.4 GHz and 12–50 GHz
  • Methods: DR for conductors TE011/TE021, PC-FPOR 12–50 GHz

Semiconductors

  • Parameters: σ, ρ, Rs (Ω/sq)
  • Frequencies: 5 GHz (other on request) and 1.1–15 GHz
  • Methods: SiPDR 5 GHz, SPDR 1.1–15 GHz

Absorbers

  • Parameters: Rs (Ω/sq), Zs
  • Method: SiPDR

Ferromagnetics

  • Parameters: FMR linewidth (ΔH)
  • Methods: ΔH broadband cavity, ΔH cavity

What you receive

  • Report with methodology, conditions, and uncertainty notes
  • Extracted parameters (Dk, Df, Rs, σ/ρ) and resonance/Q data
  • Charts and tables (vs frequency and/or temperature as applicable)
  • Raw data (CSV/Touchstone) on request
  • Confidential handling & NDA support

Sample requirements

Solid dielectrics
SPDR
  • Planar samples with clean edges; useful area ≥ ~30×30 mm
  • Thickness 0.6–6 mm (band-dependent); diameters 14–120 mm
  • Provide base material, thickness, any metallisation
FPOR
  • Discs or sheets Ø 50–150 mm; thickness 1 µm–3 mm
  • Room temperature by default; 0–80 °C on request
  • If anisotropic, specify in-plane axes
TE01δ
  • Sample diameter & height ~0.25–0.6 of cavity size
  • Temperature range 0–110 °C or per setup
Q-SCR
  • Planar squares 40–100 mm; thickness up to ~4 mm
  • Note coatings, porosity, anisotropy or bonding layers
Liquids
FPOR liquids 15–50 GHz
  • Provide liquid type and safety datasheet
  • Room temperature; Gaussian steps ~1.5 GHz
DR/Cavity liquids 110–170 GHz
  • Specify test cell volume and material compatibility
  • Room temperature measurements
Conductors
DR conductors TE011/TE021
  • Squares 23–60 mm; thickness ≥ 3 skin depths
  • State metal type and surface finish; for copper-clad give laminate data
PC-FPOR conductors 12–50 GHz
  • Discs Ø 150–195 mm; ≥ 5 skin depths
  • Provide target conductivity range if known
Semiconductors
SiPDR
  • Planar wafers or films; expected Rs or ρ to configure setup
  • Films from few µm up to ~1 mm; diameters 30–90 mm
  • For films on substrates: give substrate Dk and thickness
SPDR
  • Planar coupons; useful area ≥ ~30×30 mm
  • Thickness 0.6–6 mm depending on band
Absorbers
SiPDR
  • Provide expected Rs range and sample size
  • Planar samples recommended for repeatability
Ferromagnetics
ΔH setups
  • Provide sample geometry (sphere, rod) and material
  • We will confirm cavity size and field conditions