12.5.8 Lumped Impedances Info
The button in Info tab or with Lumped Impedances Info->Lumped Impedances Info… command from main menu or context menu invoke Lumped Impedances Info dialogue for viewing the information about all lumped impedance elements defined in the project.
The Lumped Impedances Info dialogue can also be invoked when Test Mesh window is opened, using button from Mesh tab of QW-Simulator Ribbon or Lumped Impedances command from Mesh menu of QW-Simulator main menu.
The list contains all lumped impedances defined in the project and their names, types and components are displayed. Each lumped impedance element from the list can be selected and its visual representation is displayed in the Info frame.
The Show button changes the Mesh display to show the selected lumped impedance element in the chosen Plane.
The Info… button invokes Lumped Element Info dialogue for viewing the parameters of the lumped impedance element selected from the list.
The Dynamic… button invokes Lumped Element Info dialogue for viewing the parameters of the lumped impedance element in a dynamic mode – the parameters are displayed for the lumped impedance element pointed by mouse cursor in Mesh display or LC display
It is advised to refer to Lumped impedance element for more information regarding lumped impedance elements.